Description:
The 6KG DCP/ABC Dry Chemical Powder Fire Extinguisher is a heavy-duty portable fire protection solution designed for commercial buildings, industrial facilities, warehouses, workshops, offices, shops, garages, large vehicles, and other areas with increased fire risks.
It uses Dry Chemical Powder (DCP) as the extinguishing agent and provides multi-purpose protection against Class A, Class B, and Class C fires. The 6kg capacity provides increased extinguishing-agent volume compared with smaller portable extinguishers, making it suitable for locations requiring greater fire-fighting capacity.
The extinguisher is constructed with a high-strength steel cylinder and features a built-in pressure gauge for convenient pressure-status checking. A wall mounting bracket is included for secure and accessible placement.
The unit is supplied pre-filled and fully pressurized, allowing it to be ready for emergency deployment when properly installed, inspected, and maintained.
Key Features:
- 6kg Dry Chemical Powder (DCP) capacity
- ABC multi-class fire protection
- Suitable for Class A, B and C fires
- 34B fire rating referenced
- High-strength steel cylinder
- Corrosion-resistant construction
- Built-in pressure gauge
- Wall mounting bracket included
- Pre-filled and fully pressurized
- Approximate discharge time: 21–28 seconds
- Operating temperature approximately -30°C to 55°C
- ISO 9001 certification referenced
- Suitable for commercial and industrial applications
- Suitable for workshops, garages and vehicles
- Designed for rapid emergency fire suppression
Technical Specifications:
| Specification | Details |
|---|---|
| Product Type | 6KG DCP/ABC Fire Extinguisher |
| Extinguishing Agent | Dry Chemical Powder (DCP) |
| Capacity | 6 kg |
| Fire Protection Classes | Class A, B & C |
| Fire Rating | 34B |
| Cylinder Material | High-Strength Steel |
| Cylinder Diameter | Approx. 150 mm |
| Filled/Gross Weight | Approx. 10.3 kg |
| Working Pressure | 15 Bar |
| Service Pressure | 18 Bar |
| Test Pressure | 35 Bar |
| Pressure Gauge | Built-In |
| Wall Mount Bracket | Included |
| Discharge Time | Approx. 21–28 seconds |
| Operating Temperature | Approx. -30°C to 55°C |
| Trolley | Without Trolley |
| Certification | ISO 9001 Referenced |
| Condition | Pre-Filled & Pressurized |
The supplied references specify 6kg capacity, Class A/B/C protection, 34B rating, steel construction, pressure gauge, wall bracket, discharge time, pressure specifications, and operating temperature.
Fire Classes:
Class A – Ordinary Combustible Materials
Suitable for appropriate fires involving common solid combustible materials such as:
- Wood
- Paper
- Cardboard
- Cloth
- Fabric
- Some plastics
Class B – Flammable Liquids
Suitable for appropriate fires involving flammable liquids such as:
- Petrol
- Diesel
- Kerosene
- Paint
- Solvents
- Oils
Class C – Flammable Gases
Suitable for appropriate fires involving combustible gases such as:
- LPG
- Propane
- Butane
- Other flammable gases
Electrical Fire Protection
Dry Chemical Powder extinguishers are commonly selected for many electrical-fire risks because the extinguishing agent does not rely on water. However, the exact electrical application should always follow the extinguisher’s labeling and applicable safety requirements.
Never use an extinguisher on energized electrical equipment unless it is specifically rated and approved for that application.
The supplied references describe the DCP extinguisher as suitable for electrical/energized fire risks and utility or electrical areas.
Recommended Applications:
The 6KG DCP/ABC Fire Extinguisher is suitable for:
- Industrial facilities
- Factories
- Warehouses
- Commercial buildings
- Offices
- Shops
- Workshops
- Garages
- Vehicle workshops
- Large vehicles and transport applications
- Machinery areas
- Utility rooms
- Electrical areas
- Server and equipment rooms
- Public facilities
- General commercial fire-risk areas
The references identify commercial buildings, industrial premises, warehouses, electrical/utility areas, workshops, garages, offices, shops, and transport applications.
How to Use – PASS Method:
P – Pull: Pull the safety pin from the operating handle.
A – Aim: Aim the discharge nozzle toward the base of the fire from a safe distance.
S – Squeeze: Squeeze the handle to release the dry chemical powder.
S – Sweep: Sweep the nozzle from side to side across the base of the flames until the fire is controlled.
Only attempt to extinguish a fire when it is manageable and you have a safe, unobstructed escape route.
Important Safety Instructions:
- Keep the extinguisher in an easily accessible location.
- Mount it securely using the supplied wall bracket where appropriate.
- Check the pressure gauge regularly.
- Keep the extinguisher visible and unobstructed.
- Do not use an extinguisher that is damaged, discharged, or has lost pressure.
- Protect the cylinder from severe physical impact and unsuitable storage conditions.
- Do not expose the extinguisher to temperatures outside its specified operating range.
- Have the extinguisher professionally inspected and serviced according to applicable fire-safety requirements.
- Recharge or replace the extinguisher after use.
- Never put yourself at unnecessary risk while attempting to fight a fire.
- Evacuate immediately if the fire becomes uncontrollable or blocks your escape route.
Benefits:
6KG High-Capacity Fire Protection
The 6kg DCP capacity provides greater extinguishing-agent capacity than smaller portable models, making it suitable for commercial, industrial, and higher-risk environments.
ABC Multi-Purpose Protection
The DCP extinguishing agent is designed to provide protection against suitable Class A, B and C fire hazards.
34B Fire Rating
The supplied MJS specification lists a 34B fire rating, providing an additional product specification for flammable-liquid fire performance.
Built-In Pressure Gauge
The pressure gauge allows users to quickly check the extinguisher’s pressure status and readiness.
Durable Steel Construction
The high-strength steel cylinder is designed for durability and reliable storage of the pressurized extinguishing agent.
Ready for Emergency Deployment
The extinguisher is supplied pre-filled and pressurized, allowing it to be deployed quickly when required.
Wall-Mountable Design
The included mounting bracket helps keep the extinguisher secure, visible, and readily accessible.








Shah Saad –
Ordered total of 5 extinguishers. One already fitted. Extinguishers are imported having excellent built quality with correct pressure as evident from the needle position. Payment was in advance and product delivered within 3 days.
Ahsan Shah –
Great support from this company/trader’s.
Professional, trustworthy & polite in handling queries.